The “Fisiocomputer ET2 ELECTROTHERAPY” is one of the most advanced electrotherapy devices and more practical in the market today, it has TWO INDEPENDENT CHANNELS that can deliver at the same time two different types of power among those whose ET2 features.
The ET2 also stands out for its practicality and functionality that have allowed it to be appreciated over the years by those who have used it in various physical therapy centers.
Like all the electronic apparatus of the J&S also the “fisiocomputer ET2” has several preset protocols specifically for various diseases.
Below are listed the waveforms that this latest generation apparatus is capable of delivering:
Current Diadynamic Barnard (Dya) Obtained from the straightening of a sinusoid-base which was originally at 50 Hz (and instead now, with the ET2, is selectable frequency from 30 to 100 Hz), have inhibitory effect on the conduction of sensory endings, and are in fact the most used between the electrotherapy to relieve pain.
Since the addiction it is the main problem, the ET2 generates eight different types with the unique ability to program sequences at will of the operator with automatic polarity reversal for both single fdo that at the end of the sequence.
MF (single-phase) half-wave;
DF (difase): Full wave;
nS1 (syncopated 1): alternating MF and Pause (1 +1 S);
S6 (syncopated 6): alternating MF and Pause (6 +6 S);
CP (Short Period): alternating MF and DF (1 +1 S);
LP (Long-term): alternating MF and DF (6 +6 S);
MM (Single Phase Modulated): MF with amplitude modulation;
DM (Difase Modulated): DF with amplitude modulation.Transcutaneous Electrical Nerve Stimulator (TENS)
Characterized by the typical waveform with “overshoot” negative, this current excites predominantly the nerve fibers of large diameter, by inhibiting the nociceptive stimuli than those of small diameter. With the ET2 is possible to adjust both the repetition frequency of the pulses within the package (in the range from 30 to 100 Hz), that the duration of the packet itself (from 10 ms to 10 S) and the pause duration of emission (from 0.5 to 4 S).Muscle Stimulation single-pulse (SM)
Is used both for the stimulation of muscle fibers innervated that partially denervated. It is also possible to use for the detection of the curve “Intensity/Time” (given the possibility to ET2 of down up to 1 mS pulse duration). The ET2 allows the selection of one of eight different pulse shapes. Are obviously adjustable both the pulse duration from 1 to 200 mS that the repetition period, from 0.5 to 4 S